TIMP-1 Lateral Flow Kit

For Research Use Only

 

Product name:

Product number:

Format: 

Assay type: 

Sample type:

Detection method: 

Assay time:  

Sensitivity: 

Assay range: 

Precision:  

 

Recovery (Urine):

Recovery (Serum):

Linearity (Urine):

Linearity (Serum): 

Specificity:

B.I.T.S. TIMP-1 Lateral Flow Kit

BTIMP1LF

Lateral Flow assay

Lateral Flow

Urine & Serum

Visual

10 minutes

0.23ng/mL

0.82-200 ng/mL

Intra-assay CV% < 5.4

Inter-assay CV % < 8.0

Average 111.1% Range 104 – 123.8%

Average 108.1% Range 85.9 – 120.4%

1 in 5, 1 in 10, 1 in 20 with recovery: Urine – <85.9% Serum <112.1%

1 in 200K, 1 in 400K, 1 in 800K, with recovery < 103.2%

Tissue inhibitor of metalloproteinase-1 (TIMP1) from elastin.

DeviceDrop5

Interested?

If you are interested in what you have seen here,

Contact us for more details


The unique B.I.T.S.® TIMP-1 Lateral Flow Assay Kit has been developed by Mologic to provide fast, accurate assays of TIMP-1 in urine and serum. It’s unique because it has been tested against TIMP-2, IL-1 beta, IL-4, IL-6, IL-8, IL-10, TNF alpha, MMP-8 and MMP-9 for cross-reactivity. The B.I.T.S.® assay needs no sample work-up.

The simple procedure makes it compatible with any research laboratory with basic lateral flow visualisation.

Refined and simplified step-wise procedure minimises operator error and significantly reduces time between sampling and results. Time saved in executing the assay will give you more time to do more research.

Kits manufactured to the highest quality by Mologic scientists who have developed these assays from scratch to ensure stability and batch to batch reproducibility are better than industry standards. Despite this commitment to quality, the price of the kits is in line with the competition – quality without compromise.

Mologic has invested time and resources over the past 5 years into the task of producing anti-TIMP-1 antibodies of the highest possible quality, with tailor-made specificity and sensitivity to ensure that the assay gives the right sensitivity and specificity for use in research on metastatic and non-metastatic malignancies as well as chronic inflammatory diseases such as rheumatoid arthritis and periodontitis [3].

The structure and function of the extracellular matrix (ECM) is vital in a number of physiological processes including embryonic development, tissue repair and remodelling [1]. ECM structure is ultimately regulated by the balance of extracellular proteases and protease inhibitors. Imbalance of this is implicated in rheumatoid arthritis, tumour cell invasion and metastasis [2].


PRODUCT OVERVIEW

The family of proteins called tissue inhibitors of metalloproteinase (TIMPs) are endogenous inhibitors of matrix metalloproteinase (MMP) function. To date four isoforms have been identified. Differences in specificity and expression profiles are key in the strict structural regulation of the ECM. TIMP-1 has high affinity for MMP-9 but also shows inhibitory activity against a broad range of MMPs. TIMP-1 is involved in a number of pathologies that cause or require tissue remodelling and has been implicated in metastatic and non-metastatic malignancies as well as chronic inflammatory diseases such as rheumatoid arthritis and periodontitis [3].

Plasma levels of TIMP-1 in healthy individuals have been shown to range from 48 to 211ng/ml [4].

TIMP1AssayFormat


ASSAY PROCEDURE

1. Equilibrate all materials and prepared reagents to room temperature (18-25˚C) prior to use.

2. Remove the lateral flow device from its pouch and place it on a flat surface and test within 10 minutes of opening.

3. Remove device from the foil pouch just prior to use and use within 10 minutes.

 

4. Add 80μL of diluted sample to the round well at the base of the device using a pipette.

5. Read the test line result against the score card exactly 10 minutes after adding the sample to the device.

6. Any trace of a pink line in the test area indicates a positive result. Any results read outside 10 minutes should be considered invalid and must be repeated.

TIMP1 AssayRunningDiag

 

TIMP-1AssayFlowDiag

CALCULATIONS

Determine the unknown sample concentration from the score card and multiply the value by the dilution factor 5 (for urine) or 50 (for serum).

TYPICAL STANDARD CURVE

Data provided for demonstration purposes only. A typical standard curve is shown below with the standards starting at 150ng/mL. The standard curve can be used to determine unknown levels of TIMP-1 in urine samples.

TIMP1GraphNTable

SENSITIVITY

The lowest level of detection (LLOD) of TIMP-1 is typically 0.23ng/mL. The LLOD was determined by adding three standard deviations from the mean reader value of twenty zero standard replicates and calculating the corresponding concentration.


REFERENCES

[1] Frantz C et al. The extracellular matrix at a glance. Journal of Cell Science (2010). 123, 4195-4200.

[2] Löffeck S et al. Biological role of matrix metalloproteinases: a critical balance. European Respiratory Journal (2011). 38, 191–208.

[3] Gómez D E, et al. Tissue inhibitors of metalloproteinases: structure, regulation and biological functions. European Journal of Cell Biology (1997). 74: 111–122.

[4] Oblak I et al. Differences in plasma TIMP-1 levels between healthy people and patients with rectal cancer stage II or III. Radiology & Oncology (2011). 45(3): 209–212.


Interested?

If you are interested in what you have seen here, you can now buy it from us!

Contact us for more details

Lab statistics

image for Hours in the lab
Hours in the lab

67500

so far this year

image for Peptides synthesised
Peptides synthesised

10

this year to-date

image for Problems solved
Problems solved

79

this year

image for Assays completed
Assays completed

2700

this month

EXPLORE WHAT WE CAN DO AT MOLOGIC

Take a look at our expertise. And if you can't see exactly what you're after, contact us. We'll be delighted to discuss your project with you.

Contact us